{"id":194784,"date":"2024-09-09T11:11:36","date_gmt":"2024-09-09T09:11:36","guid":{"rendered":"https:\/\/www.rse-web.it\/pubblicazioni\/aging-test-protocol-for-lithium-ion-cells\/"},"modified":"2024-09-09T11:12:30","modified_gmt":"2024-09-09T09:12:30","slug":"aging-test-protocol-for-lithium-ion-cells","status":"publish","type":"pubblicazioni","link":"https:\/\/www.rse-web.it\/en\/publications\/aging-test-protocol-for-lithium-ion-cells\/","title":{"rendered":"Aging test protocol for Lithium-ion cells"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>The article describes a test protocol developed for estimating the useful life of electrical storage systems under varying working conditions. It reports the results of the aging tests carried out on three lithium-ion cells to validate the protocol.<\/p>\n","protected":false},"author":93,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"tags":[652,1302,1373,1324,1301],"targets":[],"pubblicazioni_tipologie":[778],"class_list":["post-194784","pubblicazioni","type-pubblicazioni","status-publish","hentry","tag-active-networks","tag-batteries","tag-electricalstorage","tag-electricity-network-en","tag-sodium-ion-batteries","pubblicazioni_tipologie-paper-en"],"acf":{"dont_show_hompage":true,"projects":{"ID":191041,"post_author":"464","post_date":"2024-07-10 15:54:35","post_date_gmt":"2024-07-10 13:54:35","post_content":"","post_title":"Storage systems, including electrochemical and power-to-gas, and their interfaces with grids","post_excerpt":"The more ambitious the decarbonisation goals become, the more important energy storage is. The increasing penetration of non-programmable renewable energy sources (NPRESs) and the growing electrification of transport lead to a number of challenges related to the stability and flexibility of the national electrical system. The need to store excess renewable energy for later use where and when it is needed becomes evident.","post_status":"publish","comment_status":"open","ping_status":"closed","post_password":"","post_name":"storage-systems-including-electrochemical-and-power-to-gas-and-their-interfaces-with-grids","to_ping":"","pinged":"","post_modified":"2024-08-09 15:49:26","post_modified_gmt":"2024-08-09 13:49:26","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.rse-web.it\/progetti\/storage-systems-including-electrochemical-and-power-to-gas-and-their-interfaces-with-grids\/","menu_order":0,"post_type":"progetti","post_mime_type":"","comment_count":"0","filter":"raw"},"order_posts":"","dont_show_search":false,"related_posts":false,"show_on_slider":false,"single_post_data":{"titolo_spot":"","post_content":"<p>The article describes a test protocol developed with the aim of building an aging model for electrical storage systems and estimating their useful life under varying working conditions. The definitions of indicators of the aging of electrochemical accumulators are introduced, obtained on the basis of certain diagnostic parameters. The test protocol was initially tested on three lithium-ion cells. The article summarizes the results of the tests carried out and provides suggestions for carrying out further aging tests on the batteries.<\/p>\n","scarica_file":[{"download_option":"download","file_name":"Download Memory","download":{"ID":163113,"id":163113,"title":"19005056","filename":"19005056.pdf","filesize":836167,"url":"https:\/\/www.rse-web.it\/wp-content\/uploads\/2021\/12\/19005056.pdf","link":"https:\/\/www.rse-web.it\/en\/pubblicazioni\/aging-test-protocol-for-lithium-ion-cells\/attachment\/19005056\/","alt":"","author":"93","description":"","caption":"","name":"19005056","status":"inherit","uploaded_to":163112,"date":"2021-12-17 13:35:16","modified":"2021-12-17 13:35:16","menu_order":0,"mime_type":"application\/pdf","type":"application","subtype":"pdf","icon":"https:\/\/www.rse-web.it\/wp-includes\/images\/media\/document.png"}}],"link_estreno":false,"button":{"text":"","link":""},"referente_group":false,"data_emissione":"2019-09-20","autori":"L. Pellegrino, E. Micolano RSE S.p.A.","destinazione":"2019 AEIT International Annual Conference, Florence, September 18-20, 2019","rif_rse":"19005056"},"satellite_post_url":""},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Aging test protocol for Lithium-ion cells - RSE<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rse-web.it\/publications\/aging-test-protocol-for-lithium-ion-cells\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Aging test protocol for Lithium-ion cells - RSE\" \/>\n<meta property=\"og:description\" content=\"The article describes a test protocol developed for estimating the useful life of electrical storage systems under varying working conditions. It reports the results of the aging tests carried out on three lithium-ion cells to validate the protocol.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rse-web.it\/publications\/aging-test-protocol-for-lithium-ion-cells\/\" \/>\n<meta property=\"og:site_name\" content=\"RSE\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-09T09:12:30+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.rse-web.it\/publications\/aging-test-protocol-for-lithium-ion-cells\/\",\"url\":\"https:\/\/www.rse-web.it\/publications\/aging-test-protocol-for-lithium-ion-cells\/\",\"name\":\"Aging test protocol for Lithium-ion cells - RSE\",\"isPartOf\":{\"@id\":\"https:\/\/www.rse-web.it\/#website\"},\"datePublished\":\"2024-09-09T09:11:36+00:00\",\"dateModified\":\"2024-09-09T09:12:30+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.rse-web.it\/publications\/aging-test-protocol-for-lithium-ion-cells\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.rse-web.it\/publications\/aging-test-protocol-for-lithium-ion-cells\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.rse-web.it\/publications\/aging-test-protocol-for-lithium-ion-cells\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rse-web.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Aging test protocol for Lithium-ion cells\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.rse-web.it\/#website\",\"url\":\"https:\/\/www.rse-web.it\/\",\"name\":\"RSE\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.rse-web.it\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.rse-web.it\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.rse-web.it\/#organization\",\"name\":\"RSE\",\"url\":\"https:\/\/www.rse-web.it\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png\",\"contentUrl\":\"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png\",\"width\":734,\"height\":164,\"caption\":\"RSE\"},\"image\":{\"@id\":\"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Aging test protocol for Lithium-ion cells - RSE","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rse-web.it\/publications\/aging-test-protocol-for-lithium-ion-cells\/","og_locale":"en_US","og_type":"article","og_title":"Aging test protocol for Lithium-ion cells - RSE","og_description":"The article describes a test protocol developed for estimating the useful life of electrical storage systems under varying working conditions. It reports the results of the aging tests carried out on three lithium-ion cells to validate the protocol.","og_url":"https:\/\/www.rse-web.it\/publications\/aging-test-protocol-for-lithium-ion-cells\/","og_site_name":"RSE","article_modified_time":"2024-09-09T09:12:30+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rse-web.it\/publications\/aging-test-protocol-for-lithium-ion-cells\/","url":"https:\/\/www.rse-web.it\/publications\/aging-test-protocol-for-lithium-ion-cells\/","name":"Aging test protocol for Lithium-ion cells - RSE","isPartOf":{"@id":"https:\/\/www.rse-web.it\/#website"},"datePublished":"2024-09-09T09:11:36+00:00","dateModified":"2024-09-09T09:12:30+00:00","breadcrumb":{"@id":"https:\/\/www.rse-web.it\/publications\/aging-test-protocol-for-lithium-ion-cells\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rse-web.it\/publications\/aging-test-protocol-for-lithium-ion-cells\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.rse-web.it\/publications\/aging-test-protocol-for-lithium-ion-cells\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rse-web.it\/en\/"},{"@type":"ListItem","position":2,"name":"Aging test protocol for Lithium-ion cells"}]},{"@type":"WebSite","@id":"https:\/\/www.rse-web.it\/#website","url":"https:\/\/www.rse-web.it\/","name":"RSE","description":"","publisher":{"@id":"https:\/\/www.rse-web.it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rse-web.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.rse-web.it\/#organization","name":"RSE","url":"https:\/\/www.rse-web.it\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/","url":"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png","contentUrl":"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png","width":734,"height":164,"caption":"RSE"},"image":{"@id":"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/"}}]}},"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/pubblicazioni\/194784","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/pubblicazioni"}],"about":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/types\/pubblicazioni"}],"author":[{"embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/users\/93"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/comments?post=194784"}],"version-history":[{"count":2,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/pubblicazioni\/194784\/revisions"}],"predecessor-version":[{"id":194786,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/pubblicazioni\/194784\/revisions\/194786"}],"wp:attachment":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/media?parent=194784"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/tags?post=194784"},{"taxonomy":"targets","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/targets?post=194784"},{"taxonomy":"pubblicazioni_tipologie","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/pubblicazioni_tipologie?post=194784"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}