{"id":198945,"date":"2024-11-15T11:01:16","date_gmt":"2024-11-15T10:01:16","guid":{"rendered":"https:\/\/www.rse-web.it\/pubblicazioni\/calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil\/"},"modified":"2024-11-15T11:06:14","modified_gmt":"2024-11-15T10:06:14","slug":"calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil","status":"publish","type":"pubblicazioni","link":"https:\/\/www.rse-web.it\/en\/publications\/calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil\/","title":{"rendered":"Calculation of AC Losses in a 500 kJ\/200 kW MultifilamentaryMgB2 SMES Coil"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>The paper shows the main result of the DRYSE^MES4GRID project about the AC losses evaluation of a SMES made with MgB2 material.<\/p>\n","protected":false},"author":93,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"tags":[1324,1399],"targets":[1317],"pubblicazioni_tipologie":[773],"class_list":["post-198945","pubblicazioni","type-pubblicazioni","status-publish","hentry","tag-electricity-network-en","tag-superconductivity","targets-research","pubblicazioni_tipologie-isi-article-en"],"acf":{"dont_show_hompage":true,"projects":{"ID":188403,"post_author":"464","post_date":"2024-06-13 15:10:08","post_date_gmt":"2024-06-13 13:10:08","post_content":"","post_title":"Evolution, planning, scheduling and operation of power grids","post_excerpt":"The goal of the project is the pursuit of efficient management of the Italian electricity system that meets, in evolving scenarios, criteria of security and quality of operation, adequacy and resilience, ensuring a system-based approach. ","post_status":"publish","comment_status":"open","ping_status":"closed","post_password":"","post_name":"evolution-planning-scheduling-and-operation-of-power-grids","to_ping":"","pinged":"","post_modified":"2024-07-02 10:31:45","post_modified_gmt":"2024-07-02 08:31:45","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.rse-web.it\/progetti\/evolution-planning-scheduling-and-operation-of-power-grids\/","menu_order":0,"post_type":"progetti","post_mime_type":"","comment_count":"0","filter":"raw"},"order_posts":"","dont_show_search":false,"related_posts":false,"show_on_slider":false,"single_post_data":{"titolo_spot":"","post_content":"<p>SMES technology based on MgB2 superconductor and cryogenic-free cooling can offer a viable solution to power-intensive storage in the short term. One of the main obstacles to the development of dry-cooled SMES systems is the heat load removal due to the AC loss of the superconductor during fast charging and discharging cycles at high power.<\/p>\n<p>&nbsp;<\/p>\n<p>Accurate knowledge of the amount and distribution of AC loss in the coil is of paramount importance for the sizing and the design of the cooling system and for assessing the possible operational limits of the technology. In this manuscript, the AC loss of a 500 kJ\/200 kW multifilamentary MgB2 SMES during charge\u2013discharge cycling at full power is numerically investigated.<\/p>\n<p>&nbsp;<\/p>\n<p>The methodology and assumptions of the calculation are briefly resumed, and numerical results are reported and discussed in detail. In particular, the time profile and the distribution of the dissipated power all over the coil are reported. An average dissipation of 85.5 mW\/m is found all over the coil during one charge\u2013discharge cycle at full power, with a peak of 150.1 mW\/m in the turns lying at the ends of the coil.<\/p>\n","scarica_file":false,"link_estreno":[{"link_text":"Download Publication","link":"https:\/\/www.mdpi.com\/1996-1073\/16\/4\/1596"}],"button":{"text":"","link":""},"referente_group":false,"data_emissione":"2023-02-05","autori":"A. Morandi, M. Fabbri, P. L. Ribani, F. Lo Franco, R. Mandrioli (Universit\u00e0 di Bologna), U. Melaccio, D. Magrassi, M. Neri, A. Capelluto, M. Tropeano (ASG Superconductors), C. Gandolfi (RSE S.p.A.)","destinazione":"MDPI Energies, Vol. 35, N. 101138","rif_rse":"23008510"},"satellite_post_url":""},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Calculation of AC Losses in a 500 kJ\/200 kW MultifilamentaryMgB2 SMES Coil - RSE<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rse-web.it\/en\/publications\/calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Calculation of AC Losses in a 500 kJ\/200 kW MultifilamentaryMgB2 SMES Coil - RSE\" \/>\n<meta property=\"og:description\" content=\"The paper shows the main result of the DRYSE^MES4GRID project about the AC losses evaluation of a SMES made with MgB2 material.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rse-web.it\/en\/publications\/calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil\/\" \/>\n<meta property=\"og:site_name\" content=\"RSE\" \/>\n<meta property=\"article:modified_time\" content=\"2024-11-15T10:06:14+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.rse-web.it\/en\/publications\/calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil\/\",\"url\":\"https:\/\/www.rse-web.it\/en\/publications\/calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil\/\",\"name\":\"Calculation of AC Losses in a 500 kJ\/200 kW MultifilamentaryMgB2 SMES Coil - RSE\",\"isPartOf\":{\"@id\":\"https:\/\/www.rse-web.it\/#website\"},\"datePublished\":\"2024-11-15T10:01:16+00:00\",\"dateModified\":\"2024-11-15T10:06:14+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.rse-web.it\/en\/publications\/calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.rse-web.it\/en\/publications\/calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.rse-web.it\/en\/publications\/calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rse-web.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Calculation of AC Losses in a 500 kJ\/200 kW MultifilamentaryMgB2 SMES Coil\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.rse-web.it\/#website\",\"url\":\"https:\/\/www.rse-web.it\/\",\"name\":\"RSE\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.rse-web.it\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.rse-web.it\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.rse-web.it\/#organization\",\"name\":\"RSE\",\"url\":\"https:\/\/www.rse-web.it\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png\",\"contentUrl\":\"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png\",\"width\":734,\"height\":164,\"caption\":\"RSE\"},\"image\":{\"@id\":\"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Calculation of AC Losses in a 500 kJ\/200 kW MultifilamentaryMgB2 SMES Coil - RSE","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rse-web.it\/en\/publications\/calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil\/","og_locale":"en_US","og_type":"article","og_title":"Calculation of AC Losses in a 500 kJ\/200 kW MultifilamentaryMgB2 SMES Coil - RSE","og_description":"The paper shows the main result of the DRYSE^MES4GRID project about the AC losses evaluation of a SMES made with MgB2 material.","og_url":"https:\/\/www.rse-web.it\/en\/publications\/calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil\/","og_site_name":"RSE","article_modified_time":"2024-11-15T10:06:14+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rse-web.it\/en\/publications\/calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil\/","url":"https:\/\/www.rse-web.it\/en\/publications\/calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil\/","name":"Calculation of AC Losses in a 500 kJ\/200 kW MultifilamentaryMgB2 SMES Coil - RSE","isPartOf":{"@id":"https:\/\/www.rse-web.it\/#website"},"datePublished":"2024-11-15T10:01:16+00:00","dateModified":"2024-11-15T10:06:14+00:00","breadcrumb":{"@id":"https:\/\/www.rse-web.it\/en\/publications\/calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rse-web.it\/en\/publications\/calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.rse-web.it\/en\/publications\/calculation-of-ac-losses-in-a-500-kj-200-kw-multifilamentarymgb2-smes-coil\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rse-web.it\/en\/"},{"@type":"ListItem","position":2,"name":"Calculation of AC Losses in a 500 kJ\/200 kW MultifilamentaryMgB2 SMES Coil"}]},{"@type":"WebSite","@id":"https:\/\/www.rse-web.it\/#website","url":"https:\/\/www.rse-web.it\/","name":"RSE","description":"","publisher":{"@id":"https:\/\/www.rse-web.it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rse-web.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.rse-web.it\/#organization","name":"RSE","url":"https:\/\/www.rse-web.it\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/","url":"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png","contentUrl":"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png","width":734,"height":164,"caption":"RSE"},"image":{"@id":"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/"}}]}},"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/pubblicazioni\/198945","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/pubblicazioni"}],"about":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/types\/pubblicazioni"}],"author":[{"embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/users\/93"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/comments?post=198945"}],"version-history":[{"count":5,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/pubblicazioni\/198945\/revisions"}],"predecessor-version":[{"id":198950,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/pubblicazioni\/198945\/revisions\/198950"}],"wp:attachment":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/media?parent=198945"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/tags?post=198945"},{"taxonomy":"targets","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/targets?post=198945"},{"taxonomy":"pubblicazioni_tipologie","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/pubblicazioni_tipologie?post=198945"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}