{"id":204083,"date":"2025-05-28T17:25:51","date_gmt":"2025-05-28T15:25:51","guid":{"rendered":"https:\/\/www.rse-web.it\/pubblicazioni\/seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration\/"},"modified":"2025-05-28T17:26:39","modified_gmt":"2025-05-28T15:26:39","slug":"seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration","status":"publish","type":"pubblicazioni","link":"https:\/\/www.rse-web.it\/en\/publications\/seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration\/","title":{"rendered":"Seasonal Thermochemical Heat Storage (S-TCHS): experimental results in a medium-scale Test Facility and implementation of an innovative separate reactor configuration"},"content":{"rendered":"\n<figure class=\"wp-block-table\"><table class=\"has-fixed-layout\"><tbody><tr><td><\/td><\/tr><\/tbody><\/table><\/figure>\n","protected":false},"excerpt":{"rendered":"<p>The experimental test aims to evaluate the performance of seasonal thermochemical storage technology using 13X zeolite in a fixed-bed reactor and analyzing the effect of air inlet conditions. During the test, it was revealed that about 18% of the material was lost due to damage.<\/p>\n","protected":false},"author":93,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"tags":[1363,1300,1307,1299],"targets":[1304,1317],"pubblicazioni_tipologie":[778],"class_list":["post-204083","pubblicazioni","type-pubblicazioni","status-publish","hentry","tag-electrochemical-storage","tag-industrial-sector","tag-renewable-energy-en","tag-storage-en","targets-industrial-world","targets-research","pubblicazioni_tipologie-paper-en"],"acf":{"dont_show_hompage":true,"projects":{"ID":188409,"post_author":"93","post_date":"2024-06-13 15:10:21","post_date_gmt":"2024-06-13 13:10:21","post_content":"","post_title":"Electrochemical and thermal storage technologies","post_excerpt":"The goal of this project is to develop electrochemical and thermal storage technologies with improved performance and greater environmental and economic sustainability by optimizing the use of resources, material formulations and synthesis methods, diagnostic and control processes, and prototype design.","post_status":"publish","comment_status":"open","ping_status":"closed","post_password":"","post_name":"electrochemical-and-thermal-storage-technologies","to_ping":"","pinged":"","post_modified":"2024-07-06 15:23:41","post_modified_gmt":"2024-07-06 13:23:41","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.rse-web.it\/progetti\/electrochemical-and-thermal-storage-technologies\/","menu_order":0,"post_type":"progetti","post_mime_type":"","comment_count":"0","filter":"raw"},"order_posts":"","dont_show_search":false,"related_posts":false,"show_on_slider":false,"single_post_data":{"titolo_spot":"","post_content":"<p>This work is aimed at the experimental analysis of thermochemical seasonal heat storage technology with separate reactors with the integration of a pneumatic pellet handling system. A Test Facility was set up to test the performance of a thermochemical heat storage material, zeolite 13X, in a 1 kg fixed bed reactor.<\/p>\n<p>&nbsp;<\/p>\n<p>At a first stage, a preliminary experimental series was carried out to demonstrate the effectiveness of the system in combination with the reactive phases of the process. The air inlet conditions (air humidity ratio and mass flow rate) were varied to investigate their effects on the performance indicators, especially the released thermal power.<\/p>\n<p>&nbsp;<\/p>\n<p>Finally, the sorbent handling system was tested with subsequent cycles to evaluate the damage that the material would withstand; at the end of a 15 cycles test, about 18% of the material was lost due to pulverization and fragmentation.<\/p>\n","scarica_file":false,"link_estreno":[{"link_text":"Download Publication","link":"\/wp-content\/uploads\/2025\/05\/Seasonal-Thermochemical-Heat-Storage-S-TCHS-experimental-results-in-a-medium-scale-Test-Facility-and-implementation-of-an-innovative-separate-reactor-configuration.pdf"}],"button":{"text":"","link":""},"referente_group":false,"data_emissione":"2024-06-21","autori":"E. Patrucco, P. Castellazzi, A. Rossetti (RSE S.p.A.)","destinazione":"18th International KES Conference Smart Digital Futures 2024, Santa Cruz, Madeira 19-21 Giugno 2024","rif_rse":"24007805"},"satellite_post_url":""},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Seasonal Thermochemical Heat Storage (S-TCHS): experimental results in a medium-scale Test Facility and implementation of an innovative separate reactor configuration - RSE<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rse-web.it\/en\/publications\/seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Seasonal Thermochemical Heat Storage (S-TCHS): experimental results in a medium-scale Test Facility and implementation of an innovative separate reactor configuration - RSE\" \/>\n<meta property=\"og:description\" content=\"The experimental test aims to evaluate the performance of seasonal thermochemical storage technology using 13X zeolite in a fixed-bed reactor and analyzing the effect of air inlet conditions. During the test, it was revealed that about 18% of the material was lost due to damage.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rse-web.it\/en\/publications\/seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration\/\" \/>\n<meta property=\"og:site_name\" content=\"RSE\" \/>\n<meta property=\"article:modified_time\" content=\"2025-05-28T15:26:39+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.rse-web.it\/en\/publications\/seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration\/\",\"url\":\"https:\/\/www.rse-web.it\/en\/publications\/seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration\/\",\"name\":\"Seasonal Thermochemical Heat Storage (S-TCHS): experimental results in a medium-scale Test Facility and implementation of an innovative separate reactor configuration - RSE\",\"isPartOf\":{\"@id\":\"https:\/\/www.rse-web.it\/#website\"},\"datePublished\":\"2025-05-28T15:25:51+00:00\",\"dateModified\":\"2025-05-28T15:26:39+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.rse-web.it\/en\/publications\/seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.rse-web.it\/en\/publications\/seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.rse-web.it\/en\/publications\/seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rse-web.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Seasonal Thermochemical Heat Storage (S-TCHS): experimental results in a medium-scale Test Facility and implementation of an innovative separate reactor configuration\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.rse-web.it\/#website\",\"url\":\"https:\/\/www.rse-web.it\/\",\"name\":\"RSE\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.rse-web.it\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.rse-web.it\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.rse-web.it\/#organization\",\"name\":\"RSE\",\"url\":\"https:\/\/www.rse-web.it\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png\",\"contentUrl\":\"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png\",\"width\":734,\"height\":164,\"caption\":\"RSE\"},\"image\":{\"@id\":\"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Seasonal Thermochemical Heat Storage (S-TCHS): experimental results in a medium-scale Test Facility and implementation of an innovative separate reactor configuration - RSE","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rse-web.it\/en\/publications\/seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration\/","og_locale":"en_US","og_type":"article","og_title":"Seasonal Thermochemical Heat Storage (S-TCHS): experimental results in a medium-scale Test Facility and implementation of an innovative separate reactor configuration - RSE","og_description":"The experimental test aims to evaluate the performance of seasonal thermochemical storage technology using 13X zeolite in a fixed-bed reactor and analyzing the effect of air inlet conditions. During the test, it was revealed that about 18% of the material was lost due to damage.","og_url":"https:\/\/www.rse-web.it\/en\/publications\/seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration\/","og_site_name":"RSE","article_modified_time":"2025-05-28T15:26:39+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rse-web.it\/en\/publications\/seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration\/","url":"https:\/\/www.rse-web.it\/en\/publications\/seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration\/","name":"Seasonal Thermochemical Heat Storage (S-TCHS): experimental results in a medium-scale Test Facility and implementation of an innovative separate reactor configuration - RSE","isPartOf":{"@id":"https:\/\/www.rse-web.it\/#website"},"datePublished":"2025-05-28T15:25:51+00:00","dateModified":"2025-05-28T15:26:39+00:00","breadcrumb":{"@id":"https:\/\/www.rse-web.it\/en\/publications\/seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rse-web.it\/en\/publications\/seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.rse-web.it\/en\/publications\/seasonal-thermochemical-heat-storage-s-tchs-experimental-results-in-a-medium-scale-test-facility-and-implementation-of-an-innovative-separate-reactor-configuration\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rse-web.it\/en\/"},{"@type":"ListItem","position":2,"name":"Seasonal Thermochemical Heat Storage (S-TCHS): experimental results in a medium-scale Test Facility and implementation of an innovative separate reactor configuration"}]},{"@type":"WebSite","@id":"https:\/\/www.rse-web.it\/#website","url":"https:\/\/www.rse-web.it\/","name":"RSE","description":"","publisher":{"@id":"https:\/\/www.rse-web.it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rse-web.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.rse-web.it\/#organization","name":"RSE","url":"https:\/\/www.rse-web.it\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/","url":"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png","contentUrl":"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png","width":734,"height":164,"caption":"RSE"},"image":{"@id":"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/"}}]}},"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/pubblicazioni\/204083","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/pubblicazioni"}],"about":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/types\/pubblicazioni"}],"author":[{"embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/users\/93"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/comments?post=204083"}],"version-history":[{"count":2,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/pubblicazioni\/204083\/revisions"}],"predecessor-version":[{"id":204085,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/pubblicazioni\/204083\/revisions\/204085"}],"wp:attachment":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/media?parent=204083"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/tags?post=204083"},{"taxonomy":"targets","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/targets?post=204083"},{"taxonomy":"pubblicazioni_tipologie","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/pubblicazioni_tipologie?post=204083"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}