{"id":192350,"date":"2024-08-27T15:39:50","date_gmt":"2024-08-27T13:39:50","guid":{"rendered":"https:\/\/www.rse-web.it\/rapporti\/adrc-controls-for-power-converters-in-direct-current-distribution-networks\/"},"modified":"2024-09-20T09:35:38","modified_gmt":"2024-09-20T07:35:38","slug":"adrc-controls-for-power-converters-in-direct-current-distribution-networks","status":"publish","type":"rapporti","link":"https:\/\/www.rse-web.it\/en\/reports\/adrc-controls-for-power-converters-in-direct-current-distribution-networks\/","title":{"rendered":"ADRC controls for power converters in direct current distribution networks"},"content":{"rendered":"<p class=\"last-updated-date\">Recently updated on September 20th, 2024 at 09:35 am<\/p>","protected":false},"excerpt":{"rendered":"<p>The document provides a thorough theoretical analysis of the ADRC controller for first-order systems, directly compared with a traditional PI controller. To complement the theoretical study, both ADRC and PI controllers are used in the model of a single-phase DAB converter to regulate the voltage of a direct current (DC) network. The strengths and weaknesses of the two controllers are highlighted in response to various types of disturbances and changes in network parameters. <\/p>\n","protected":false},"author":93,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"tags":[1324,1377,1634],"targets":[1304,1317],"rapporti_tipologie":[762],"class_list":["post-192350","rapporti","type-rapporti","status-publish","hentry","tag-electricity-network-en","tag-monitoring-and-control","tag-dc-microgrids","targets-industrial-world","targets-research","rapporti_tipologie-report-en"],"acf":{"projects":{"ID":191050,"post_author":"464","post_date":"2024-07-10 16:51:19","post_date_gmt":"2024-07-10 14:51:19","post_content":"","post_title":"Architecture and management models of the electrical system and grids","post_excerpt":"The project aims to develop methodologies, software tools, prototypes and demonstrators to optimise electric transmission and distribution grids, as well as new architecture and system management models and new regulatory schemes that encourage the integration of renewable and non-programmable generation, self-generation, storage systems and aggregators, and that take into account electric penetration.","post_status":"publish","comment_status":"open","ping_status":"closed","post_password":"","post_name":"architecture-and-management-models-of-the-electrical-system-and-grids","to_ping":"","pinged":"","post_modified":"2024-08-21 12:10:45","post_modified_gmt":"2024-08-21 10:10:45","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.rse-web.it\/progetti\/architecture-and-management-models-of-the-electrical-system-and-grids\/","menu_order":0,"post_type":"progetti","post_mime_type":"","comment_count":"0","filter":"raw"},"order_posts":"","dont_show_search":false,"related_posts":false,"dont_show_hompage":false,"show_on_slider":false,"single_post_data":{"titolo_spot":"","post_content":"<p>This work is related to the development of direct current (DC) systems in distribution networks.<\/p>\n<p>A review of the scientific literature on the Active Disturbance Rejection Control (ADRC) method was conducted to assess its applicability to a case study involving converters in a Medium Voltage Direct Current (MVDC) network for deriving Low Voltage Direct Current (LVDC) networks. The ADRC control method is compared with traditional control strategies such as Proportional, Integral, Derivative, or PI(D) control. The report is structured as follows:<\/p>\n<p>Chapter 1 presents the state of the art, highlighting that control systems in industrial\/energy sectors are predominantly centered around PI(D) regulators.<\/p>\n<p>Chapter 2 introduces ADRC control, formalizing the frequency response of the ADRC regulator mathematically, allowing for a comparison with the PI structure. General formulas are derived to ensure that the control action of the ADRC regulator is equivalent to that of a PI regulator in all cases.<\/p>\n<p>Chapter 3 offers a comparison between the implementations of the two control schemes, ADRC and PI, based on the results from the previous chapter.<\/p>\n<p>Chapter 4 provides simulation results for voltage control of a Dual Active Bridge (DAB) converter that powers an increasingly complex LVDC network. The performance in response to network disturbances is compared for both control architectures (ADRC and PI) using the synthesis procedures presented in the preceding chapters.<\/p>\n<p>Chapter 5 extends the equivalent model of the MVDC network to provide a more accurate representation of the power supply network and the phenomena that may arise. The regulators (ADRC and PI) are then evaluated not only based on their effectiveness in regulating the output voltage from the DAB but also on their ability to contain oscillations in its input voltage. Under these operating conditions, the ADRC regulator achieves superior performance compared to the PI, driven by a different synthesis strategy for the parameters.<\/p>\n<p>In the conclusion, in addition to highlighting the performance improvement achieved with ADRC control, its greater robustness compared to PI control is also noted, especially in relation to variations in the equivalent model parameters when they are not fully known or are highly variable.<\/p>\n","link_estreno":false,"scarica_file":[{"download_option":"download","file_name":"Download Report","download":{"ID":166927,"id":166927,"title":"20010112","filename":"20010112.pdf","filesize":2080394,"url":"https:\/\/www.rse-web.it\/wp-content\/uploads\/2022\/05\/20010112.pdf","link":"https:\/\/www.rse-web.it\/en\/rapporti\/controlli-adrc-per-convertitori-elettronici-di-potenza-inseriti-in-reti-di-distribuzione-in-corrente-continua\/attachment\/20010112\/","alt":"","author":"93","description":"","caption":"","name":"20010112","status":"inherit","uploaded_to":166926,"date":"2022-05-17 15:59:36","modified":"2022-05-17 15:59:36","menu_order":0,"mime_type":"application\/pdf","type":"application","subtype":"pdf","icon":"https:\/\/www.rse-web.it\/wp-includes\/images\/media\/document.png"}}],"button":{"text":"","link":""},"referente_group":false,"data_emissione":"2020-12-30","autori":"A. Clerici, R. M. Chiumeo, D. Raggini, A. Veroni (RSE S.P.A.)","rapporto":"","rif_rse":"20010112"},"satellite_post_url":""},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>ADRC controls for power converters in direct current distribution networks - RSE<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rse-web.it\/en\/reports\/adrc-controls-for-power-converters-in-direct-current-distribution-networks\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"ADRC controls for power converters in direct current distribution networks - RSE\" \/>\n<meta property=\"og:description\" content=\"The document provides a thorough theoretical analysis of the ADRC controller for first-order systems, directly compared with a traditional PI controller. To complement the theoretical study, both ADRC and PI controllers are used in the model of a single-phase DAB converter to regulate the voltage of a direct current (DC) network. The strengths and weaknesses of the two controllers are highlighted in response to various types of disturbances and changes in network parameters.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rse-web.it\/en\/reports\/adrc-controls-for-power-converters-in-direct-current-distribution-networks\/\" \/>\n<meta property=\"og:site_name\" content=\"RSE\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-20T07:35:38+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.rse-web.it\/en\/reports\/adrc-controls-for-power-converters-in-direct-current-distribution-networks\/\",\"url\":\"https:\/\/www.rse-web.it\/en\/reports\/adrc-controls-for-power-converters-in-direct-current-distribution-networks\/\",\"name\":\"ADRC controls for power converters in direct current distribution networks - RSE\",\"isPartOf\":{\"@id\":\"https:\/\/www.rse-web.it\/#website\"},\"datePublished\":\"2024-08-27T13:39:50+00:00\",\"dateModified\":\"2024-09-20T07:35:38+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.rse-web.it\/en\/reports\/adrc-controls-for-power-converters-in-direct-current-distribution-networks\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.rse-web.it\/en\/reports\/adrc-controls-for-power-converters-in-direct-current-distribution-networks\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.rse-web.it\/en\/reports\/adrc-controls-for-power-converters-in-direct-current-distribution-networks\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rse-web.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"ADRC controls for power converters in direct current distribution networks\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.rse-web.it\/#website\",\"url\":\"https:\/\/www.rse-web.it\/\",\"name\":\"RSE\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.rse-web.it\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.rse-web.it\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.rse-web.it\/#organization\",\"name\":\"RSE\",\"url\":\"https:\/\/www.rse-web.it\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png\",\"contentUrl\":\"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png\",\"width\":734,\"height\":164,\"caption\":\"RSE\"},\"image\":{\"@id\":\"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"ADRC controls for power converters in direct current distribution networks - RSE","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rse-web.it\/en\/reports\/adrc-controls-for-power-converters-in-direct-current-distribution-networks\/","og_locale":"en_US","og_type":"article","og_title":"ADRC controls for power converters in direct current distribution networks - RSE","og_description":"The document provides a thorough theoretical analysis of the ADRC controller for first-order systems, directly compared with a traditional PI controller. To complement the theoretical study, both ADRC and PI controllers are used in the model of a single-phase DAB converter to regulate the voltage of a direct current (DC) network. The strengths and weaknesses of the two controllers are highlighted in response to various types of disturbances and changes in network parameters.","og_url":"https:\/\/www.rse-web.it\/en\/reports\/adrc-controls-for-power-converters-in-direct-current-distribution-networks\/","og_site_name":"RSE","article_modified_time":"2024-09-20T07:35:38+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rse-web.it\/en\/reports\/adrc-controls-for-power-converters-in-direct-current-distribution-networks\/","url":"https:\/\/www.rse-web.it\/en\/reports\/adrc-controls-for-power-converters-in-direct-current-distribution-networks\/","name":"ADRC controls for power converters in direct current distribution networks - RSE","isPartOf":{"@id":"https:\/\/www.rse-web.it\/#website"},"datePublished":"2024-08-27T13:39:50+00:00","dateModified":"2024-09-20T07:35:38+00:00","breadcrumb":{"@id":"https:\/\/www.rse-web.it\/en\/reports\/adrc-controls-for-power-converters-in-direct-current-distribution-networks\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rse-web.it\/en\/reports\/adrc-controls-for-power-converters-in-direct-current-distribution-networks\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.rse-web.it\/en\/reports\/adrc-controls-for-power-converters-in-direct-current-distribution-networks\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rse-web.it\/en\/"},{"@type":"ListItem","position":2,"name":"ADRC controls for power converters in direct current distribution networks"}]},{"@type":"WebSite","@id":"https:\/\/www.rse-web.it\/#website","url":"https:\/\/www.rse-web.it\/","name":"RSE","description":"","publisher":{"@id":"https:\/\/www.rse-web.it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rse-web.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.rse-web.it\/#organization","name":"RSE","url":"https:\/\/www.rse-web.it\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/","url":"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png","contentUrl":"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png","width":734,"height":164,"caption":"RSE"},"image":{"@id":"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/"}}]}},"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/rapporti\/192350","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/rapporti"}],"about":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/types\/rapporti"}],"author":[{"embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/users\/93"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/comments?post=192350"}],"version-history":[{"count":2,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/rapporti\/192350\/revisions"}],"predecessor-version":[{"id":197011,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/rapporti\/192350\/revisions\/197011"}],"wp:attachment":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/media?parent=192350"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/tags?post=192350"},{"taxonomy":"targets","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/targets?post=192350"},{"taxonomy":"rapporti_tipologie","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/rapporti_tipologie?post=192350"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}