{"id":192465,"date":"2024-08-27T16:57:32","date_gmt":"2024-08-27T14:57:32","guid":{"rendered":"https:\/\/www.rse-web.it\/rapporti\/experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump\/"},"modified":"2024-09-19T14:47:46","modified_gmt":"2024-09-19T12:47:46","slug":"experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump","status":"publish","type":"rapporti","link":"https:\/\/www.rse-web.it\/en\/reports\/experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump\/","title":{"rendered":"Experimental study of the performance of an ejector for integration with a heat pump"},"content":{"rendered":"<p class=\"last-updated-date\">Recently updated on September 19th, 2024 at 02:47 pm<\/p>","protected":false},"excerpt":{"rendered":"<p>The third year of the project envisaged first of all a complex experimental activity aimed at verifying the ability of the (previously developed) CFD model to describe and analyze the functioning of a variable geometry ejector in a propane cycle. Subsequently, a model of a heat pump involving the inclusion of an ejector in a standard cycle was developed in order to evaluate the potential energy savings for this type of scheme in the residential heating sector.<\/p>\n","protected":false},"author":93,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"tags":[1391,1310,1628,1364],"targets":[1317],"rapporti_tipologie":[762],"class_list":["post-192465","rapporti","type-rapporti","status-publish","hentry","tag-climate-control","tag-decarbonization","tag-fluid-dynamic-modeling","tag-residential-sector","targets-research","rapporti_tipologie-report-en"],"acf":{"projects":{"ID":191045,"post_author":"464","post_date":"2024-07-10 16:22:44","post_date_gmt":"2024-07-10 14:22:44","post_content":"","post_title":"Technologies for efficient penetration of the electric carrier into end uses","post_excerpt":"The project aims to promote efficient solutions that can reduce energy consumption and foster the development of technologies for converting electricity into other forms of energy or converting thermal energy, including solar or environmental energy, into electrical, thermal and cooling energy.","post_status":"publish","comment_status":"open","ping_status":"closed","post_password":"","post_name":"technologies-for-efficient-penetration-of-the-electric-carrier-into-end-uses","to_ping":"","pinged":"","post_modified":"2024-08-09 15:54:16","post_modified_gmt":"2024-08-09 13:54:16","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.rse-web.it\/progetti\/technologies-for-efficient-penetration-of-the-electric-carrier-into-end-uses\/","menu_order":0,"post_type":"progetti","post_mime_type":"","comment_count":"0","filter":"raw"},"order_posts":"","dont_show_search":false,"related_posts":false,"dont_show_hompage":false,"show_on_slider":false,"single_post_data":{"titolo_spot":"","post_content":"<p>This report describes the work carried out in the third year of a three-year project aimed at developing an innovative ejector-equipped heat pump architecture, with the goal of contributing to the penetration of electric technologies for residential air conditioning, in accordance with the NECP growth estimates required to meet the national decarbonization targets to 2030. During the first year, an extensive literature review of ejector refrigeration systems was carried out, highlighting their peculiar characteristics and the dependence of performance on the ejector&#8217;s internal fluid dynamics and the characteristics of the refrigerants, among which propane seems to be one of the best performing.<br \/>\nThe second year&#8217;s activity focused on defining a modeling approach for the simulation of supersonic ejectors. Two modeling methods (namely concentrating-parameter &#8211; LPM &#8211; and thermo-fluid-computational &#8211; CFD) were developed and compared, both of which were validated through matching with literature data collected in the first year, determining the superiority of the CFD approach in predicting ejector performance parameters with satisfactory accuracy. A prototype moving-pin ejector was also designed for the purposes of subsequent experiments.<br \/>\nThe third-year activity first involved experimental verification of the CFD model&#8217;s ability to describe and analyze the operation of a variable-geometry ejector in a propane cycle. The experimentation involved building the ejector, constructing a test circuit, and performing a series of tests aimed at verifying the operation of the ejector in a variable regime and the ability of the CFD model to replicate the experimental results. Subsequently, a useful modeling tool was developed to evaluate possible energy-saving effects in the residential air conditioning sector. The model based on a heat pump scheme involving the addition of an ejector in a standard refrigeration cycle was validated with literature data and used to make a comparison with the performance of a standard propane cycle under the conditions required by traditional radiator heating systems.<\/p>\n","link_estreno":false,"scarica_file":[{"download_option":"download","file_name":"Download Report","download":{"ID":173102,"id":173102,"title":"21010138","filename":"21010138.pdf","filesize":5557824,"url":"https:\/\/www.rse-web.it\/wp-content\/uploads\/2022\/11\/21010138.pdf","link":"https:\/\/www.rse-web.it\/en\/rapporti\/studio-sperimentale-delle-prestazioni-di-un-eiettore-per-integrazione-con-pompa-di-calore\/attachment\/21010138\/","alt":"","author":"93","description":"","caption":"","name":"21010138","status":"inherit","uploaded_to":173101,"date":"2022-11-08 12:26:23","modified":"2022-11-08 12:26:23","menu_order":0,"mime_type":"application\/pdf","type":"application","subtype":"pdf","icon":"https:\/\/www.rse-web.it\/wp-includes\/images\/media\/document.png"}}],"button":{"text":"","link":""},"referente_group":false,"data_emissione":"2021-12-31","autori":"L. Croci, V. Brignoli, S. Viani (RSE S.p.A.), G. Besagni, F. Inzoli (PoliMI)","rapporto":"","rif_rse":"21010138"},"satellite_post_url":""},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Experimental study of the performance of an ejector for integration with a heat pump - RSE<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rse-web.it\/en\/reports\/experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Experimental study of the performance of an ejector for integration with a heat pump - RSE\" \/>\n<meta property=\"og:description\" content=\"The third year of the project envisaged first of all a complex experimental activity aimed at verifying the ability of the (previously developed) CFD model to describe and analyze the functioning of a variable geometry ejector in a propane cycle. Subsequently, a model of a heat pump involving the inclusion of an ejector in a standard cycle was developed in order to evaluate the potential energy savings for this type of scheme in the residential heating sector.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rse-web.it\/en\/reports\/experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump\/\" \/>\n<meta property=\"og:site_name\" content=\"RSE\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-19T12:47:46+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.rse-web.it\/en\/reports\/experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump\/\",\"url\":\"https:\/\/www.rse-web.it\/en\/reports\/experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump\/\",\"name\":\"Experimental study of the performance of an ejector for integration with a heat pump - RSE\",\"isPartOf\":{\"@id\":\"https:\/\/www.rse-web.it\/#website\"},\"datePublished\":\"2024-08-27T14:57:32+00:00\",\"dateModified\":\"2024-09-19T12:47:46+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.rse-web.it\/en\/reports\/experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.rse-web.it\/en\/reports\/experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.rse-web.it\/en\/reports\/experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rse-web.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Experimental study of the performance of an ejector for integration with a heat pump\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.rse-web.it\/#website\",\"url\":\"https:\/\/www.rse-web.it\/\",\"name\":\"RSE\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.rse-web.it\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.rse-web.it\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.rse-web.it\/#organization\",\"name\":\"RSE\",\"url\":\"https:\/\/www.rse-web.it\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png\",\"contentUrl\":\"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png\",\"width\":734,\"height\":164,\"caption\":\"RSE\"},\"image\":{\"@id\":\"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Experimental study of the performance of an ejector for integration with a heat pump - RSE","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rse-web.it\/en\/reports\/experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump\/","og_locale":"en_US","og_type":"article","og_title":"Experimental study of the performance of an ejector for integration with a heat pump - RSE","og_description":"The third year of the project envisaged first of all a complex experimental activity aimed at verifying the ability of the (previously developed) CFD model to describe and analyze the functioning of a variable geometry ejector in a propane cycle. Subsequently, a model of a heat pump involving the inclusion of an ejector in a standard cycle was developed in order to evaluate the potential energy savings for this type of scheme in the residential heating sector.","og_url":"https:\/\/www.rse-web.it\/en\/reports\/experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump\/","og_site_name":"RSE","article_modified_time":"2024-09-19T12:47:46+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rse-web.it\/en\/reports\/experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump\/","url":"https:\/\/www.rse-web.it\/en\/reports\/experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump\/","name":"Experimental study of the performance of an ejector for integration with a heat pump - RSE","isPartOf":{"@id":"https:\/\/www.rse-web.it\/#website"},"datePublished":"2024-08-27T14:57:32+00:00","dateModified":"2024-09-19T12:47:46+00:00","breadcrumb":{"@id":"https:\/\/www.rse-web.it\/en\/reports\/experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rse-web.it\/en\/reports\/experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.rse-web.it\/en\/reports\/experimental-study-of-the-performance-of-an-ejector-for-integration-with-a-heat-pump\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rse-web.it\/en\/"},{"@type":"ListItem","position":2,"name":"Experimental study of the performance of an ejector for integration with a heat pump"}]},{"@type":"WebSite","@id":"https:\/\/www.rse-web.it\/#website","url":"https:\/\/www.rse-web.it\/","name":"RSE","description":"","publisher":{"@id":"https:\/\/www.rse-web.it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rse-web.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.rse-web.it\/#organization","name":"RSE","url":"https:\/\/www.rse-web.it\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/","url":"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png","contentUrl":"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png","width":734,"height":164,"caption":"RSE"},"image":{"@id":"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/"}}]}},"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/rapporti\/192465","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/rapporti"}],"about":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/types\/rapporti"}],"author":[{"embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/users\/93"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/comments?post=192465"}],"version-history":[{"count":2,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/rapporti\/192465\/revisions"}],"predecessor-version":[{"id":196901,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/rapporti\/192465\/revisions\/196901"}],"wp:attachment":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/media?parent=192465"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/tags?post=192465"},{"taxonomy":"targets","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/targets?post=192465"},{"taxonomy":"rapporti_tipologie","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/rapporti_tipologie?post=192465"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}