{"id":195538,"date":"2024-09-12T10:01:19","date_gmt":"2024-09-12T08:01:19","guid":{"rendered":"https:\/\/www.rse-web.it\/rapporti\/use-of-pmus-for-fault-detection-and-location-in-medium-voltage-distribution-networks\/"},"modified":"2024-09-12T10:03:25","modified_gmt":"2024-09-12T08:03:25","slug":"use-of-pmus-for-fault-detection-and-location-in-medium-voltage-distribution-networks","status":"publish","type":"rapporti","link":"https:\/\/www.rse-web.it\/en\/reports\/use-of-pmus-for-fault-detection-and-location-in-medium-voltage-distribution-networks\/","title":{"rendered":"Use of PMUs for Fault Detection and Location in Medium Voltage Distribution Networks"},"content":{"rendered":"","protected":false},"excerpt":{"rendered":"<p>This report describes the analysis of several methods in the literature dedicated to protecting distribution networks using Phase Measurement Units (PMUs). A literature review was conducted, and the document summarizes the key elements.<\/p>\n","protected":false},"author":464,"featured_media":0,"comment_status":"open","ping_status":"closed","template":"","meta":{"_acf_changed":false,"footnotes":""},"tags":[652,1315],"targets":[1317],"rapporti_tipologie":[762],"class_list":["post-195538","rapporti","type-rapporti","status-publish","hentry","tag-active-networks","tag-smart-grids-en","targets-research","rapporti_tipologie-report-en"],"acf":{"dont_show_hompage":true,"projects":{"ID":191050,"post_author":"464","post_date":"2024-07-10 16:51:19","post_date_gmt":"2024-07-10 14:51:19","post_content":"","post_title":"Architecture and management models of the electrical system and grids","post_excerpt":"The project aims to develop methodologies, software tools, prototypes and demonstrators to optimise electric transmission and distribution grids, as well as new architecture and system management models and new regulatory schemes that encourage the integration of renewable and non-programmable generation, self-generation, storage systems and aggregators, and that take into account electric penetration.","post_status":"publish","comment_status":"open","ping_status":"closed","post_password":"","post_name":"architecture-and-management-models-of-the-electrical-system-and-grids","to_ping":"","pinged":"","post_modified":"2024-08-21 12:10:45","post_modified_gmt":"2024-08-21 10:10:45","post_content_filtered":"","post_parent":0,"guid":"https:\/\/www.rse-web.it\/progetti\/architecture-and-management-models-of-the-electrical-system-and-grids\/","menu_order":0,"post_type":"progetti","post_mime_type":"","comment_count":"0","filter":"raw"},"order_posts":"","dont_show_search":false,"related_posts":false,"show_on_slider":false,"single_post_data":{"titolo_spot":"","post_content":"<p>The development of PMU (Phase Measurement Unit) devices dedicated to medium and low voltage distribution networks and characterized by a lower cost compared to solutions designed for high voltage can be a valid solution for monitoring and observability of distribution networks. In this perspective, obtaining fault detection and location capabilities from the same device, which can be used to implement actual protection algorithms, would offer the advantage of having different functionalities for network operation included in a single measurement device.<\/p>\n<p>In this context, the activity reported in the document aims to analyze several methods described in the literature for the protection of distribution networks using PMU devices, in order to critically evaluate their performance in terms of the effectiveness of the protection function and fault section selection. A literature review on the subject was conducted, from which the most significant methods were extracted and analyzed. The proposed methods are based on different assumptions, such as the number of PMU devices employed or the use of so-called pseudo-measurements to compensate for the lack of measurements when a limited number of devices are installed in the network. Another important distinguishing factor for some methods is the need for precise knowledge of the network parameters under examination.<\/p>\n","link_estreno":false,"scarica_file":[{"download_option":"download","file_name":"Download Report","download":{"ID":105774,"id":105774,"title":"19012871-319159.pdf","filename":"19012871-319159.pdf","filesize":1869953,"url":"https:\/\/www.rse-web.it\/wp-content\/uploads\/2021\/03\/19012871-319159.pdf","link":"https:\/\/www.rse-web.it\/en\/rapporti\/19012871\/19012871-319159\/","alt":"","author":"464","description":"19012871-319159.pdf","caption":"","name":"19012871-319159","status":"inherit","uploaded_to":132854,"date":"2021-12-31 00:00:00","modified":"2021-03-17 12:50:09","menu_order":0,"mime_type":"application\/pdf","type":"application","subtype":"pdf","icon":"https:\/\/www.rse-web.it\/wp-includes\/images\/media\/document.png"}}],"button":{"text":"","link":""},"referente_group":false,"data_emissione":"2019-12-31","autori":"M. Cabiati, B. Gabriele \"Universit\u00e0 di Genova\", F. Conte \"Universit\u00e0 di Genova\", F. Silvestro  \"Universit\u00e0 di Genova\"","rapporto":"","rif_rse":"19012871"},"satellite_post_url":""},"yoast_head":"<!-- This site is optimized with the Yoast SEO plugin v27.2 - https:\/\/yoast.com\/product\/yoast-seo-wordpress\/ -->\n<title>Use of PMUs for Fault Detection and Location in Medium Voltage Distribution Networks - RSE<\/title>\n<meta name=\"robots\" content=\"index, follow, max-snippet:-1, max-image-preview:large, max-video-preview:-1\" \/>\n<link rel=\"canonical\" href=\"https:\/\/www.rse-web.it\/rapporti\/19012871\/\" \/>\n<meta property=\"og:locale\" content=\"en_US\" \/>\n<meta property=\"og:type\" content=\"article\" \/>\n<meta property=\"og:title\" content=\"Use of PMUs for Fault Detection and Location in Medium Voltage Distribution Networks - RSE\" \/>\n<meta property=\"og:description\" content=\"This report describes the analysis of several methods in the literature dedicated to protecting distribution networks using Phase Measurement Units (PMUs). A literature review was conducted, and the document summarizes the key elements.\" \/>\n<meta property=\"og:url\" content=\"https:\/\/www.rse-web.it\/rapporti\/19012871\/\" \/>\n<meta property=\"og:site_name\" content=\"RSE\" \/>\n<meta property=\"article:modified_time\" content=\"2024-09-12T08:03:25+00:00\" \/>\n<meta name=\"twitter:card\" content=\"summary_large_image\" \/>\n<script type=\"application\/ld+json\" class=\"yoast-schema-graph\">{\"@context\":\"https:\/\/schema.org\",\"@graph\":[{\"@type\":\"WebPage\",\"@id\":\"https:\/\/www.rse-web.it\/rapporti\/19012871\/\",\"url\":\"https:\/\/www.rse-web.it\/rapporti\/19012871\/\",\"name\":\"Use of PMUs for Fault Detection and Location in Medium Voltage Distribution Networks - RSE\",\"isPartOf\":{\"@id\":\"https:\/\/www.rse-web.it\/#website\"},\"datePublished\":\"2024-09-12T08:01:19+00:00\",\"dateModified\":\"2024-09-12T08:03:25+00:00\",\"breadcrumb\":{\"@id\":\"https:\/\/www.rse-web.it\/rapporti\/19012871\/#breadcrumb\"},\"inLanguage\":\"en-US\",\"potentialAction\":[{\"@type\":\"ReadAction\",\"target\":[\"https:\/\/www.rse-web.it\/rapporti\/19012871\/\"]}]},{\"@type\":\"BreadcrumbList\",\"@id\":\"https:\/\/www.rse-web.it\/rapporti\/19012871\/#breadcrumb\",\"itemListElement\":[{\"@type\":\"ListItem\",\"position\":1,\"name\":\"Home\",\"item\":\"https:\/\/www.rse-web.it\/en\/\"},{\"@type\":\"ListItem\",\"position\":2,\"name\":\"Use of PMUs for Fault Detection and Location in Medium Voltage Distribution Networks\"}]},{\"@type\":\"WebSite\",\"@id\":\"https:\/\/www.rse-web.it\/#website\",\"url\":\"https:\/\/www.rse-web.it\/\",\"name\":\"RSE\",\"description\":\"\",\"publisher\":{\"@id\":\"https:\/\/www.rse-web.it\/#organization\"},\"potentialAction\":[{\"@type\":\"SearchAction\",\"target\":{\"@type\":\"EntryPoint\",\"urlTemplate\":\"https:\/\/www.rse-web.it\/?s={search_term_string}\"},\"query-input\":{\"@type\":\"PropertyValueSpecification\",\"valueRequired\":true,\"valueName\":\"search_term_string\"}}],\"inLanguage\":\"en-US\"},{\"@type\":\"Organization\",\"@id\":\"https:\/\/www.rse-web.it\/#organization\",\"name\":\"RSE\",\"url\":\"https:\/\/www.rse-web.it\/\",\"logo\":{\"@type\":\"ImageObject\",\"inLanguage\":\"en-US\",\"@id\":\"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/\",\"url\":\"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png\",\"contentUrl\":\"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png\",\"width\":734,\"height\":164,\"caption\":\"RSE\"},\"image\":{\"@id\":\"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/\"}}]}<\/script>\n<!-- \/ Yoast SEO plugin. -->","yoast_head_json":{"title":"Use of PMUs for Fault Detection and Location in Medium Voltage Distribution Networks - RSE","robots":{"index":"index","follow":"follow","max-snippet":"max-snippet:-1","max-image-preview":"max-image-preview:large","max-video-preview":"max-video-preview:-1"},"canonical":"https:\/\/www.rse-web.it\/rapporti\/19012871\/","og_locale":"en_US","og_type":"article","og_title":"Use of PMUs for Fault Detection and Location in Medium Voltage Distribution Networks - RSE","og_description":"This report describes the analysis of several methods in the literature dedicated to protecting distribution networks using Phase Measurement Units (PMUs). A literature review was conducted, and the document summarizes the key elements.","og_url":"https:\/\/www.rse-web.it\/rapporti\/19012871\/","og_site_name":"RSE","article_modified_time":"2024-09-12T08:03:25+00:00","twitter_card":"summary_large_image","schema":{"@context":"https:\/\/schema.org","@graph":[{"@type":"WebPage","@id":"https:\/\/www.rse-web.it\/rapporti\/19012871\/","url":"https:\/\/www.rse-web.it\/rapporti\/19012871\/","name":"Use of PMUs for Fault Detection and Location in Medium Voltage Distribution Networks - RSE","isPartOf":{"@id":"https:\/\/www.rse-web.it\/#website"},"datePublished":"2024-09-12T08:01:19+00:00","dateModified":"2024-09-12T08:03:25+00:00","breadcrumb":{"@id":"https:\/\/www.rse-web.it\/rapporti\/19012871\/#breadcrumb"},"inLanguage":"en-US","potentialAction":[{"@type":"ReadAction","target":["https:\/\/www.rse-web.it\/rapporti\/19012871\/"]}]},{"@type":"BreadcrumbList","@id":"https:\/\/www.rse-web.it\/rapporti\/19012871\/#breadcrumb","itemListElement":[{"@type":"ListItem","position":1,"name":"Home","item":"https:\/\/www.rse-web.it\/en\/"},{"@type":"ListItem","position":2,"name":"Use of PMUs for Fault Detection and Location in Medium Voltage Distribution Networks"}]},{"@type":"WebSite","@id":"https:\/\/www.rse-web.it\/#website","url":"https:\/\/www.rse-web.it\/","name":"RSE","description":"","publisher":{"@id":"https:\/\/www.rse-web.it\/#organization"},"potentialAction":[{"@type":"SearchAction","target":{"@type":"EntryPoint","urlTemplate":"https:\/\/www.rse-web.it\/?s={search_term_string}"},"query-input":{"@type":"PropertyValueSpecification","valueRequired":true,"valueName":"search_term_string"}}],"inLanguage":"en-US"},{"@type":"Organization","@id":"https:\/\/www.rse-web.it\/#organization","name":"RSE","url":"https:\/\/www.rse-web.it\/","logo":{"@type":"ImageObject","inLanguage":"en-US","@id":"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/","url":"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png","contentUrl":"https:\/\/www.rse-web.it\/wp-content\/uploads\/2024\/01\/cropped-logo_rse_2022.png","width":734,"height":164,"caption":"RSE"},"image":{"@id":"https:\/\/www.rse-web.it\/#\/schema\/logo\/image\/"}}]}},"publishpress_future_workflow_manual_trigger":{"enabledWorkflows":[]},"_links":{"self":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/rapporti\/195538","targetHints":{"allow":["GET"]}}],"collection":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/rapporti"}],"about":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/types\/rapporti"}],"author":[{"embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/users\/464"}],"replies":[{"embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/comments?post=195538"}],"version-history":[{"count":2,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/rapporti\/195538\/revisions"}],"predecessor-version":[{"id":195540,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/rapporti\/195538\/revisions\/195540"}],"wp:attachment":[{"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/media?parent=195538"}],"wp:term":[{"taxonomy":"post_tag","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/tags?post=195538"},{"taxonomy":"targets","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/targets?post=195538"},{"taxonomy":"rapporti_tipologie","embeddable":true,"href":"https:\/\/www.rse-web.it\/en\/wp-json\/wp\/v2\/rapporti_tipologie?post=195538"}],"curies":[{"name":"wp","href":"https:\/\/api.w.org\/{rel}","templated":true}]}}