Cerca nel sito per parola chiave

pubblicazioni - Articolo

Test results on MGB2 windings for AC application

pubblicazioni - Articolo

Test results on MGB2 windings for AC application

Recently updated on Maggio 11th, 2021 at 08:35 am

Luciano Martini*, Marco Bocchi*, Rossella Beatrice Dalessandro*, Davide Nardelli** Marco Modica**, Roberto Marabotto**, Matteo Tassisto**, Roberto Penco** Gianni Grasso***, D. Pietranera*** Rivista: IEEE Transactions on applied Superconductivity Vol.17, N.2, Giugno 2007 USA * CESI RICERCA ** ANSALDO SUPERCONDUTTORI *** COLUMBUS SUPERCONDUCTORS In the frame of a research and development project named LIMSAT several MgB2 tapes and windings were fabricated and tested in DC and AC current regime. All technical aspects related to the choice of the MgB2 tape layout as well as the winding technology and insulation will be reported. Different tape layout and insulating technique were used for the different windings, in particular several lengths of MgB2 multifilamentary Cu-stabilized Ni-sheathed tape. Critical current measurements on short samples of the tape used, performed in a cryogenic-free test facility, showed currents over 250 A at 20K, 1 T. Five non inductive MgB2 windings were made using lengths from about 35 to 130 m and tested in liquid He and liquid Ne. The results from electrical DC and AC tests are reported and discussed. Index Terms—AC loss, FCL, MgB2, non inductive, tape.

Progetti